Pool Pump Total Dynamic Head Flow
Calculator
Results
- Total dynamic head (m)
- 2.5
- Derated pump flow (L/min)
- 33.333333
- Derated pump flow (L/h)
- 1,999.999999
Pool and aquarium results
| Total dynamic head (m) | 2.5 |
| Derated pump flow (L/min) | 33.333333 |
| Derated pump flow (L/h) | 1,999.999999 |
formula-map diagram
- Total dynamic head (m)
- 2.5
- Derated pump flow (L/min)
- 33.333333
- Derated pump flow (L/h)
- 1,999.999999
Pool and aquarium relationship
Formula
flow ≈ rated flow × (1 − TDH ÷ rated head)= 2.5
Note
This is a simplified model: it applies a standard geometric or physical formula to the numbers you entered. Volumes assume a regular shape and an even average depth, and the kidney shape uses the common 0.45 × (A + B) × L area approximation. Chemical doses convert a target change into a product mass using the strength or label dose you enter, because the amount of active ingredient varies from product to product; they ignore pH, temperature, buffering, sunlight, bather load and existing chemical interactions. Heating uses Q = m × c × ΔT with c = 4186 J/kg·K and ignores heat losses to air, ground and evaporation; evaporation and cover figures use the rate you enter, not local weather. Aquarium stocking by surface area is a rule of thumb, not a biological limit. Always follow the product label and test the water before and after dosing, and consult a pool or aquarium professional for anything you are unsure about.
Example: with the default inputs, calculator.pool.total_dynamic_head_m is 2.5.
More in Pool and aquarium
See all →Frequently asked questions
What is total dynamic head (TDH) in this calculator?+
Here TDH is simply the static head (lift) plus the friction loss in piping and fittings, both entered in metres. It is the total head the pump has to work against.
How is the derated flow calculated?+
Flow is estimated as the rated flow multiplied by (1 minus TDH divided by the pump's rated head). The result never goes below zero.
Is this the real pump curve?+
No. It uses a simple linear approximation, while real pump curves are not straight lines. Treat the result as a rough sizing check and compare it with the manufacturer's curve.
What happens if TDH exceeds the pump's rated head?+
The derating factor drops to zero, so the calculator shows no flow. In practice, that means the pump is too small for the system as entered.
Which inputs do I need?+